COUNTERWEIGHT SETS, MANUAL -- (75) SETS

83. Counterweight System:
This Contractor shall furnish and install seventy-five (75) sets of an approved counterweight system operating on tee bar tracks, five (5) sets to support draw close-in tracks, as hereinafter specified.  Each set shall consist of eight (8) eight (8") inch diameter under hung self-lubricating loft blocks, three (3) eight (8") inch diameter ball bearing idler drums not less than four (4") inches wide to take up sag of cables, one (1) sixteen (16") inch diameter eight (8) line roller bearing head block, one (1) twelve (12") inch diameter ball bearing under hung rope block, all machine turned and mounted in steel frames, 1-1/2" steel pipe batten with slip joints with eight (8) two (2'0") foot trim chains attached to the batten with two and one-half (2-1/2") inch forged steel rings and fitted with heavy duty snap hooks.  The batten shall be hung on eight (8) five-sixteenth (5/16") inch diameter steel cables which shall be attached to the top of the counterweight frame with trim chains.  The counterweight frames shall be not less than ten (10'-0") feet long and have a capacity of 1200 pounds.  They shall be made of two and one-half inch by three-eighth inch (2-1/2" x 3/8") steel, forged to shape with two connecting rods between top and bottom to receive the intermediate weights, and there shall be spacing bars on these rods to prevent their spreading.

84.  The tops and bottoms of the counterweight frames shall have drop forged steel eyes for the cables and operating rope.  The counterweight frame shall be fitted with fibre guides which shall operate on one and one-half inch by one and one-half inch by three-sixteenth inch (1-1/2" x 1-1/2" x 3/8") steel tee bar tracks.  Each set shall have a three-quarter (3/4") inch pure manila rope operating line with a rope lock fitted to the locking rail and a nine (9") inch tension pulley.  Each frame shall have eight hundred (800) pounds of smooth gray iron counterweights of assorted sizes.  The tee bars are to be spaced by U straps and attached to one and three-quarter inch by one and three-quarter inch by three-sixteenth inch (1-3/4" x 1-3/4" x 3/8") angle battens spaced approximately four feet six inches (4'6") apart.  These battens shall extend the full length of the system and to be fabricated so that additional sets may be added at any time and shall be secured to the wall by clip angles and expansion bolts.

85.  Locking Rail:
Across the entire front of the counterweight system on the stage floor there shall be a locking rail of four (4") inch angle fitted to receive the rope locks and having a card index strip with card holders.  The locking rail shall have angle posts about four (4'0") feet apart.  These posts shall be bolted through the stage floor.

86. There shall be two (2) outriggers of one and one half (1-1/2") inch steel pipe supported by angle brackets placed in front of the system.  From the lower outrigger, there shall be suspended an electric index strip having card holders and numbered to correspond with the sets.  This index strip shall extend the full depth of the system.  This Contractor shall furnish this index strip wired but without lamps and hung in place, but the wiring between the index strip and wall outlet shall be done by others.

87.  Borderlights D and K:
Two (2) of the above sets shall carry the borderlights D and K.  These sets shall have ten (10") inch diameter ball bearing loft blocks mounted in steel frames in place of the eight (8") inch loft blocks and each of these sets shall have counterweight frames of sufficient capacity for the necessary counterweight to balance these sets.  These sets shall have additional cables and loft blocks to take care of the flying of the flexible borderlight feed cables.

88. Lighting Baffles:
This Contractor shall furnish and install lighting baffles of high grade asbestos cloth made from forty (40") inch wide sheets of asbestos cloth, with one edge seamed and equipped with grommets for hanging.  These lighting baffles shall be of lengths corresponding to the length of the borderlights.  These lighting baffles shall be furnished for all of the lighting bridges and borderlights.


89. Asbestos cloth to be painted black with cold water paint, by others.