FIRE CURTAIN (MAIN), RIGGING, MOTORIZED

72. Lifting Cables and Rigging:
Both the upper and lower frames shall be hung on twelve (12) steel lifting cables, one at each end and one at intermediate points not over ten (10’) feet apart.  These cables shall be not less than one-half (1/2”) inch diameter and shall be attached to the curtain with three-quarter (3/4”) inch turnbuckles and to the top of the counterweights with eyebolts and coil springs.  The counterweight frames shall be made of not less than six (6”) inch thick top and bottom weights connected by two (2) rods spaced to receive the intermediate counterweights. 

73.  The counterweight frames shall operate on two and one-half inch by two and one-half inch by three-eight inch (2-1/2” x 2-1/2” x 3/8”) tee bar tracks, which shall have spacing U brackets of two and one-half by three-eight inch (2-1/2” x 3/8”) iron every four (4’) feet and shall be double bolted to the wall.  The counterweight tracks shall set on the stage floor and continue for the full travel of the counterweight frame plus five (5’) feet.  The tracks at the stage floor shall be enclosed to a height of eight (8’0”) feet by a guard made of number sixteen (#16) sheet iron.

74.  For each cable, there shall be a heavy pattern twenty (20") inch diameter machine turned curtain block.  Each counterweight shall have a heavy pattern twenty-four (24") inch head block with separate machine turned grooves for each cable.   All blocks shall be securely keyed to solid shafts.  The shafts run in two (2) double roller bearing pillow blocks.  The pillow blocks shall be supported on two (2) ten (10") inch channels set parallel to the proscenium wall.  These channels shall extend across the full width of the stage and shall rest on and be securely bolted to the steel of the building. Between the upper and lower sections of the curtain there shall be a system of cables and sheaves so arranged that the two (2) sections of the curtain shall move simultaneously - both sections starting and stopping at the same time.  This system of cables and sheaves shall be of the same size as specified for the lifting cables.